<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-21 21-23-00
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 3/5, 54 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 66 kHz 5008 0,0599
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,3 dBr 5,02 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 66 kHz MIN: 13 kHz % above 76 kHz: 0,0599 Acquired: 2025/08/21 21.21.56 Total samples: 5008 Equivalent time: 0:04:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 5,9 dBr MIN: 3,3 dBr AVE: 5,02 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2025/08/21 21.21.55) 21.08 21.10 21.12 21.14 21.16 21.18 21.20 0 2 4 6 Pm [dBr]